As of November 23, 2023
Specifications and design of the products are subject to change without notice for the product improvement.
Spec Detail
| Item |
Specifications |
| Product Number |
HG-SC113 |
| Part Number |
HG-SC113 |
| Regulatory compliance |
CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
| Pollution degree |
2 |
| Operating altitude |
2000 m 6561.68 ft or less |
| Environmental resistance : Protection |
IP40 (IEC) |
| Environmental resistance : Ambient temperature |
-10 to +50 ℃ +14 to +122 ℉ (No condensation or icing), Storage: -20 to +60 ℃ -4 to +140 ℉ |
| Environmental resistance : Ambient humidity |
35 to 85 % RH, Storage: 35 to 85 % RH |
| Insulation resistance |
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Environmental resistance : Vibration resistance |
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude (10 to 58Hz), maximum acceleration 49 m/s2 (58 to 150 Hz) in X, Y and Z directions for two hours each |
| Environmental resistance : Shock resistance |
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
| Material |
Case: Polycarbonate, Cover: Polycarbonate, Switches: Polyacetal |
| Weight |
Net weight: 60 g approx. |
| Remark |
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉. |
| External inputs (Input 1, Input 2, Input 3):Trigger input |
- |
Controller
| Item |
Specifications |
| Compatible sensor head |
HG-S1010-AC,HG-S1110-AC,HG-S1010(R),HG-S1110(R),HG-S1032,HG-S1050 |
| Number of connectable units |
Up to 15 slave units can be connected per master unit. (Note):When connected to a communication unit for digital displacement sensor, up to 14 slave units can be connected per master unit. |
Controllers
| Item |
Specifications |
| Supply voltage |
24 V DC ±10 %, including ripple 0.5 V (P-P) |
| Current consumption |
70 mA or less (when sensor head is connected)(Note):Current consumption does not include analog current output. |
Controller
| Item |
Specifications |
| Analog current output |
- |
| Control outputs(Output 1, Output 2, Output 3) |
- |
| Control outputs(Output 1, Output 2, Output 3):Short-circuit protection |
- |
| Control outputs(Output 1, Output 2, Output 3):Judgment output |
- |
| Control outputs(Output 1, Output 2, Output 3):Alarm output |
- |
| External inputs (Input 1, Input 2, Input 3) |
- |
| External inputs (Input 1, Input 2, Input 3):Preset input |
- |
| External inputs (Input 1, Input 2, Input 3):Reset input |
- |
| External inputs (Input 1, Input 2, Input 3) Bank input A / B |
- |
| Response time |
3 ms, 5 ms, 10 ms, 100 ms, 500 ms, 1,000 ms switching type |
| Digital display |
204-segment LCD |
| Display resolution |
0.1μm 0.004 mil |
| Display range |
-199.9999 to 199.9999mm -7.874 to 7.874 in |
| Contamination level |
2 |
| Elevation |
2,000 m 6561.68 ft or less (Note):Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
| Environmental resistance:Voltage withstandability |
1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Cable |
- |
| Notes |
Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20℃ +68℉. |
Return to top